Full compliance with the annual fire door assembly inspection and testing in accordance with 2010 nfpa 80 is required by january 1 2018.
Nfpa annual fire door inspection checklist.
Take this online course to improve your ability to use nfpa 80.
Standard for fire doors and other opening protectives to locate interpret and correctly identify and apply the requirements for the inspection testing and maintenance of fire door assemblies.
Life safety code section 7 2 1 15 2 requires all fire and smoke doors to be inspected and tested annually including doors such as.
Fire door assembly inspection checklist the 2007 and 2010 editions of nfpa 80 standard for fire do ors and other opening protectives section 5 2 inspections require all fire doors to be inspect ed not less than annually.
However non rated doors should be routinely inspected as part of the facility maintenance program and must be maintained in proper working order.
Doors with fire protection rating labels door assemblies in exit enclosures typically stairwells and exit passageways door assemblies in smoke compartment walls hazardous rooms with rated doors it is recommended that a facility identify all doors to be inspected on a drawing layout of the facility to track inspections.
Further inspection of the nfpa 101 code requirements reveals that paragraph 8 3 3 1 requires that openings in fire resistance rated assemblies e g fire barriers be protected by approved listed and labeled fire door assemblies in accordance with nfpa 80 regardless of the occupancy.
Nfpa 80 2016 standard for fire doors and other openings protectives is the most current national standard.
The standard for fire door safety.
Swinging doors with builders hardware or fire door hardware 13 point inspection 1.
Emergency system described in nfpa 70 article 700 legally required standby described in nfpa 70 article 701 optional standby system described in nfpa 70 article 702 which also meets the performance requirements of article 700 or 701.
Cms annual inspection per nfpa 101.
According to the national fire protection association nfpa 80 section 5 2 3 5 1 fire door assemblies shall be visually inspected from both sides to access the overall condition of the door.
Nfpa inspection and testing 2 of 4.
Fire door field labeling and certification as defined in nfpa 252 or ul 10b c.
Life safety code lsc deficiencies associated with the annual inspection and testing of fire doors should be cited under k211 means of egress general.
This one hour self paced module is based on the 2016 edition of nfpa 80.
Labels are clearly visible and legible.
Independent field inspections of fire egress swingings doors frames and door hardware.
Non rated door assemblies including corridor doors to patient care rooms and smoke barrier doors are not subject to the annual inspection and testing requirements of either nfpa 80 or nfpa 105.